FAQs
Account
  • Log in
  • Register
0
LipExoGen
  • Home
  • Products
    • Reporter Lentivirus
    • Reporter Cell Lines
    • Luciferase Assay Kits
    • Gene Products
      • Lentiviral Particles
        • shRNA Lentiviral Particles
        • miRNA Lentiviral Particles
        • ORF cDNA Lentiviral Particles
        • TF Reporter Lentiviral Particles
        • Organelle & Subcellular Marker
        • Gene Promoter Lentiviral Particles
        • Luc-Fluorescent Imaging Lentiviral Particles
        • View All
      • Plasmids
        • Non-Lentiviral ORF cDNA Expression Plasmids
        • Lentiviral ORF cDNA Expression Plasmids
        • View All
    • TetOn System
    • Liposome Products
      • Cationic Liposomes
      • Drug Loaded Liposomes
      • Fluorescent Liposomes
      • Immunogenic Liposomes
      • Liposomes for Click Chemistry
      • Plain (Non-PEGylated)
      • Plain (PEGylated)
      • View All
  • Services
    • Recombinant Antibody Services
    • Lipid Nanoparticles (LNPs)
    • Liposome Synthesis
      • Liposomal Formulation Development
      • Build Your Own Regular Liposomes
      • Modify A Regular Liposome Product
    • Exosome Services
      • Exosome Isolation
      • Exosome Engineering
    • Gene Services
      • Custom Lentiviral Particles
        • Validated shRNA Lentiviral Particles
        • Custom miRNA Lentiviral Particles
        • ORF cDNA Lentiviral Particles
        • LentiCRISPR sgRNA Lentiviral Particles
        • TF Reporter Lentiviral Particles
        • Promoter Lentiviral Particles
      • Custom Gene Cloning
        • Verified shRNA Custom Cloning
        • miRNA Custom Cloning
        • ORF cDNA Custom Cloning
        • TF Reporter Custom Cloning
        • Gene Promoter Custom Cloning
        • AAV Gene Cloning
      • Gene Mutagenesis
      • Gene Regulation
  • Support
    • Order Forms
      • Custom Regular Liposome
      • Formulation Development
      • Modify Liposome Product
      • Engineered Exosomes
      • Express Exosome Isolation
      • Gene Mutagenesis
      • Gene Regulation
      • Custom shRNA Lentiviral Particles
      • Custom miRNA Lentiviral Particles
      • Custom ORF cDNA Lentiviral Particles
      • Custom LentiCRISPR sgRNA Lentiviral Particles
      • Custom TF Reporter Lentiviral Particles
      • Custom Gene Promoter Lentiviral Particles
      • shRNA Custom Cloning
      • miRNA Custom Cloning
      • ORF cDNA Custom Cloning
      • Gene Promoter Custom Cloning
      • TF Reporter Custom Cloning
    • Supporting Documents
      • Pre-Made Vectors List
      • General Vectors List 1
      • General Vectors List 2
      • General Vectors List 3
      • Lentivirus Transduction Protocol
      • Lentivirus MSDS
    • Product FAQs
    • Technical Support
  • Research
    • Drug Development
    • Immunology and Immunotherapy
    • Oncology and Chemotherapy
    • Tumor Models
  • About
  • Contact
×
LipExoGen
0
All Categories
  • Home
  • Products
    • Reporter Lentivirus
    • Reporter Cell Lines
    • Luciferase Assay Kits
    • Gene Products
      • Lentiviral Particles
        • shRNA Lentiviral Particles
        • miRNA Lentiviral Particles
        • ORF cDNA Lentiviral Particles
        • TF Reporter Lentiviral Particles
        • Organelle & Subcellular Marker
        • Gene Promoter Lentiviral Particles
        • Luc-Fluorescent Imaging Lentiviral Particles
        • View All
      • Plasmids
        • Non-Lentiviral ORF cDNA Expression Plasmids
        • Lentiviral ORF cDNA Expression Plasmids
        • View All
    • TetOn System
    • Liposome Products
      • Cationic Liposomes
      • Drug Loaded Liposomes
      • Fluorescent Liposomes
      • Immunogenic Liposomes
      • Liposomes for Click Chemistry
      • Plain (Non-PEGylated)
      • Plain (PEGylated)
      • View All
  • Services
    • Recombinant Antibody Services
    • Lipid Nanoparticles (LNPs)
    • Liposome Synthesis
      • Liposomal Formulation Development
      • Build Your Own Regular Liposomes
      • Modify A Regular Liposome Product
    • Exosome Services
      • Exosome Isolation
      • Exosome Engineering
    • Gene Services
      • Custom Lentiviral Particles
        • Validated shRNA Lentiviral Particles
        • Custom miRNA Lentiviral Particles
        • ORF cDNA Lentiviral Particles
        • LentiCRISPR sgRNA Lentiviral Particles
        • TF Reporter Lentiviral Particles
        • Promoter Lentiviral Particles
      • Custom Gene Cloning
        • Verified shRNA Custom Cloning
        • miRNA Custom Cloning
        • ORF cDNA Custom Cloning
        • TF Reporter Custom Cloning
        • Gene Promoter Custom Cloning
        • AAV Gene Cloning
      • Gene Mutagenesis
      • Gene Regulation
  • Support
    • Order Forms
      • Custom Regular Liposome
      • Formulation Development
      • Modify Liposome Product
      • Engineered Exosomes
      • Express Exosome Isolation
      • Gene Mutagenesis
      • Gene Regulation
      • Custom shRNA Lentiviral Particles
      • Custom miRNA Lentiviral Particles
      • Custom ORF cDNA Lentiviral Particles
      • Custom LentiCRISPR sgRNA Lentiviral Particles
      • Custom TF Reporter Lentiviral Particles
      • Custom Gene Promoter Lentiviral Particles
      • shRNA Custom Cloning
      • miRNA Custom Cloning
      • ORF cDNA Custom Cloning
      • Gene Promoter Custom Cloning
      • TF Reporter Custom Cloning
    • Supporting Documents
      • Pre-Made Vectors List
      • General Vectors List 1
      • General Vectors List 2
      • General Vectors List 3
      • Lentivirus Transduction Protocol
      • Lentivirus MSDS
    • Product FAQs
    • Technical Support
  • Research
    • Drug Development
    • Immunology and Immunotherapy
    • Oncology and Chemotherapy
    • Tumor Models
  • About
  • Contact
My Cart (0 )

No products in the cart.

- -
All Categories
Home Reporter Cell Lines TOPFlash Assay Wnt/β-catenin HEK293 Reporter Cell Lines
  • Previous

    NF-κB HEK293 Reporter Cell Lines

    $1,895.00

  • Next

    ARE HEK293 Reporter Cell Lines

    $1,895.00

TOPFlash Assay Wnt/β-catenin HEK293 Reporter Cell Lines

TOPFlash Assay Wnt/β-catenin HEK293 Reporter Cell Lines

Rated 0 out of 5
0 reviews
SKU: RCL-0011

$1,895.00

The TCF/LEF (Wnt/Beta-Catenin) HEK293 Reporter Cell Lines are optimized for sensitive, real-time monitoring of TCF/LEF-mediated Wnt/Beta-Catenin signaling signaling. Featuring a TCF/LEF responsive reporter construct driving fluorescent or luminescent reporter output, these cell lines enable direct analysis of TCF/LEF activity in live cells and are ideal for studying TCF/LEF-mediated Wnt/Beta-Catenin signaling pathway modulation and downstream transcriptional responses.

Have questions about this product? Our PhD-level staff is ready to assist. Email info@lipexogen.com

Category: Reporter Cell Lines Tags: Cell line, Reporters

Available Options:

  • Specifications
  • MSDS
  • Reviews (0)

Specifications

TCF/LEF (Wnt/Beta-Catenin) Reporter Cell Lines

Overview

Details

The TCF/LEF (Wnt/Beta-Catenin) HEK293 Reporter Cell Lines collection is engineered to evaluate TCF/LEF-mediated Wnt/Beta-Catenin signaling signaling activity with high precision. Produced by stable transduction with our lentiviral reporter systems, these HEK293 cells stably express a TCF/LEF responsive reporter construct reporter construct, offered in a range of formats including fluorescent or luminescent reporters. Formats may vary by availability. Upon pathway activation, TCF/LEF regulates downstream transcriptional programs that are captured by the integrated reporter. These cell lines provide flexible, ready-to-use platforms for real-time analysis of pathway modulation, transcriptional activity, and small molecule screening.

 

HEK293 (human embryonic kidney, adherent)
Human
Each vial contains 5 x 10^6 cells in 1 ml of Cell Freezing Medium
Puromycin or Blasticidin (varies by product variant)
eGFP, mCherry, or Firefly Luciferase (varies by product variant)
DMEM, 10% FBS, 2 mM L-glutamine, 100 U/ml penicillin, 100 µg/ml streptomycin
Screened and confirmed mycoplasma-free
Liquid nitrogen vapor phase
Shipped on dry ice (USA, Canada, Europe, Asia)
Pathway activation confirmed by appropriate stimulus; reporter expression validated; stable for 20+ passages
See dropdown table for available formats

 


Product Data:

Figure 1. TOPFlash EGFP Reporter Activation by LiCl in Stable HEK293 Cells TOPFlash EGFP reporter (RCL-0011-5S) stable HEK293 cells were generated using TCF/LEF

Figure 1. TOPFlash EGFP Reporter Activation by LiCl in Stable HEK293 Cells

TOPFlash EGFP reporter (RCL-0011-5S) stable HEK293 cells were generated using TCF/LEF-TAG-BSD lentiviral particles and selected with blasticidin. Cells were seeded at 5 × 104 cells per well in a 48-well plate and incubated for 8-10 hours. Cells were then treated with LiCl for 32 hours, trypsinized, and analyzed by flow cytometry to observe EGFP expression.

Figure 2. TOPFlash EGFP Reporter Activation by Human Wnt3a in Stable HEK293 Cells TOPFlash EGFP reporter (RCL-0011-5S) stable HEK293 cells were seeded at 5 × 10

Figure 2. TOPFlash EGFP Reporter Activation by Human Wnt3a in Stable HEK293 Cells

TOPFlash EGFP reporter (RCL-0011-5S) stable HEK293 cells were seeded at 5 × 104 cells per well in a 48-well plate and incubated for 8-10 hours. Cells were treated with 2.5 mM LiCl for 16 hours before addition of human Wnt3a to a final concentration of 25 ng/ml, then incubated for an additional 16 hours. Cells were then trypsinized and analyzed by flow cytometry.

Key Features:

  • Reporter system:
    • Fluorescent enable real-time detection of TCF/LEF-mediated Wnt/Beta-Catenin signaling signaling in live cells.
  • Stably integrated TCF/LEF responsive reporter construct reporter construct driving reporter expression.
  • Validated with to confirm pathway responsiveness.
  • Ideal for live-cell imaging, flow cytometry, or luminescence-based assays depending on format.

Applications:

  • Screening activators and inhibitors of the TCF/LEF-mediated Wnt/Beta-Catenin signaling pathway.
  • Studying transcriptional activity regulated by TCF/LEF-mediated Wnt/Beta-Catenin signaling in mammalian systems.
  • Evaluating TCF/LEF-mediated transcriptional regulation.
  • Fluorescence or luminescence-based readouts for high-throughput screening and mechanistic studies.

Quality Control: Each cell line is validated for reporter expression and pathway responsiveness using appropriate stimuli (e.g., ). Stable expression is confirmed for ≥20 passages. All cells are screened and certified mycoplasma-free.

Shipping and Storage: Shipped on dry ice (USA, Canada, Europe, Asia) Cells should be transferred to Liquid nitrogen vapor phase upon receipt.

How to Use: Plate cells and stimulate with the indicated pathway agonists or test compounds. Monitor reporter activity via fluorescence microscopy, flow cytometry, or luminescence detection depending on the construct.

Contents:

  • 1 vial containing 5×10^6 cells TCF/LEF (Wnt/Beta-Catenin) HEK293 Reporter Cells (variant-specific).

Materials Required but Not Supplied:

  • Media for Cell Culture:
    • Thaw Medium: DMEM, 10% FBS, 2 mM L-glutamine, 100 U/ml penicillin, 100 µg/ml streptomycin
    • Growth Medium: DMEM, 10% FBS, 2 mM L-glutamine, 100 U/ml penicillin, 100 µg/ml streptomycin
  • Materials for Reporter Assays:
    • Pathway activators and/or inhibitors as needed (e.g., )
    • 96-well tissue culture-treated assay plates
    • Fluorescence microscope, flow cytometer, or luminometer (depending on reporter format)

Background:
TCF/LEF-mediated Wnt/Beta-Catenin signaling signaling plays a central role in cellular homeostasis, development, and disease. Activation of this pathway leads to modulation of TCF/LEF activity and downstream transcriptional responses. The reporter system used in these cells leverages defined response elements and a minimal promoter to drive reporter expression, enabling sensitive and specific measurement of pathway activation. These HEK293 reporter lines offer robust tools for dissecting pathway-driven transcriptional responses and screening modulators in live cells.

These products are covered by a Limited Use License. For more information, please email info@lipexogen.com

 

MSDS

MSDS

MSDS

Reviews (0)

Reviews

There are no reviews yet.

Be the first to review “TOPFlash Assay Wnt/β-catenin HEK293 Reporter Cell Lines” Cancel reply

Your email address will not be published. Required fields are marked *

Never Miss An Update

Subscribe to our newsletter

Products

  • Liposome Products
  • Gene Products

services

  • Liposome Services
  • Exosome Services
  • Gene Services

Information

  • Contact Us
  • FAQs
  • Terms & Conditions
  • Privacy Policy
  • Terms of Sale

Account

  • My account
  • Orders
  • Cart
  • Checkout
  • Products
Lipexogen © 2026 | Site Credits

101 North Haven St, Baltimore, MD 21224

We use cookies to ensure that we give you the best experience on our website. If you continue to use this site we will assume that you are happy with it.